DSP MLTPWR/6KVA/ONLINE W/BATT

  • 2,898.05лв.

ЗАПИТВАНЕ ЗА НАЛИЧНОСТ

Само попълнете 2 полета
Ние ще се свържем с вас в рамките на работния ден.

Добави в желани

Добави за сравняване

Наличност: В наличност

Производител: INFORM

Код на продукта: DSP MLTPWR_6KVA_ONLINE W_BATT

Manufacturer  INFORM
Mnfr Part #  -
Model  MLTPWR/6KVA/ONLINE W/BATT
Capacity  6 kVA
Type  On-Line
Input  Phase Configuration: 1Ph + N + PE (Hardwire); Nominal Voltage: 220VAC/230VAC/240VAC; Minimum Voltage (at Half load): 160VAC; Minimum Voltage (at Full load): 180VAC; Maximum Voltage: 280VAC; Frequency: 45-65 Hz; Power Factor:0.99.
Output  Power Factor: 0,9; Phase Configuration: 1Ph + N + PE (Hardwire); Nominal Voltage: 220VAC / 230VAC / 240VAC; Wave Form Pure: Sine Wave; Total Harmonic Distortion: at 100% linear load: <3% and at 100% non-linear load: <5%; Frequency: 50Hz or 60Hz (adjustable); Frequency Tolerance(free running): ±0,1 %; Frequency Synchronized Range: ±1Hz, ±3Hz (selectable); Static Voltage Regulation (0%-100% load): <1%; Crest Factor: 3; Transfer Time: 0sec; Overload: Up to 10min. @100%~120%, Up to 1min. @120%~150%, Transfer to bypass @ >150%; Total Efficiency: up to 90%; Greenmode efficiency: ≥97%; Outlets: External Socket Box (2 pcs SCHUKO, 4 pcs IEC C13 Outlets) Optional.
Alarms  Audible and Visual Alarms: Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions
Display  LED + LCD Display: Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload and Transferring with Interruption & UPS Fault; LCD display: Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature; Self Diagnostics: Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking.
Battery  Type: Maintenance-free lead acid batteries; Recharge Time: 4-6h up to 90%; Voltage: 240VDC; Quantity per string: 20 pcs 12V Batteries; Internal batteries: 20 pcs 12V 4.5Ah (internal battery version only); Cold Start: Present .
Environment  Overload Protection: Bypass transfer time is calculated by simulating a temperature related model of a fuse; Short Circuit Protection: Acts as the ideal current source during the short circuit time; Other Protection: Against excessive (heat,voltage,current) intense battery discharge; Operating Temperature: 0 ˚C.... + 40 ˚C; Proposed Temp. to extend battery life: 20 - 25 ˚C; Humidity: up to 95% ( non-condensing ); Audible Noise at 1 m: <50 dB; Protection Class: IP 20.
Interface  Interface (Communication ports): Standard RS232 port and optional RS485, Internal SNMP, Dry Contact Cards; Monitoring and Management Software: Standard.
Weight  -
Standarts  EN62040-1-1 (safety); EN62040-2 (EMC);EN62040-3(performance); EN60950-1
Dimensions  -
Warranty  24 Months